Some checks failed
Windows project source guards / test (push) Failing after 3m26s
Owner decision 2026-11-29. The metrics worker calls a line that was just connected or switched to silent after 5 s of sending without an answer (10 s for a settled line); auto-switch then acts at once for a fresh line (no 20 s warm-up, no 15 s of dead pings); the line that was left is out for 1, 5, then 10 minutes and never banned; the replacement prefers another entry (second host label), the same entry only when nothing else is left. Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
159 lines
7.3 KiB
Python
159 lines
7.3 KiB
Python
"""Fast failover (owner decision 2026-11-29): a line that accepts TCP but never answers is left in about 5 s.
|
|
|
|
The rule uses only existing lines and the client's own traffic (no new probe, no new wire behaviour):
|
|
- the metrics worker calls a FRESH line (just connected or switched to) silent after 5 s of sending without an answer,
|
|
instead of 10 s, and the confirmation request through the tunnel stays the same;
|
|
- auto-switch then acts at once for a fresh line (no 20 s warm-up, no 15 s of dead pings);
|
|
- the failed line is out for 1, then 5, then 10 minutes (never banned), and the replacement prefers another ENTRY;
|
|
- the deadline is 5 s now, 3 s when the routes through Russia are gone (one constant).
|
|
|
|
Host names follow the real scheme of the rows (`<id>.<entry>.<zone>`: entries rufristal, rurugogo, timama), the zone is a
|
|
placeholder so that no real address is kept in the repository.
|
|
"""
|
|
|
|
from __future__ import annotations
|
|
|
|
import unittest
|
|
from unittest.mock import patch
|
|
|
|
from test_auto_switch_dead_link import FakeController, MetricsWorkerPingTargetTests, _tick
|
|
|
|
from xray_fluent.application import auto_switch_service
|
|
from xray_fluent.application.auto_switch_service import (
|
|
AUTO_SWITCH_BACKOFF_SEC,
|
|
AUTO_SWITCH_DEAD_LINK_SEC,
|
|
AUTO_SWITCH_FRESH_SEC,
|
|
AUTO_SWITCH_FRESH_WARMUP_SEC,
|
|
entry_key,
|
|
get_next_node_for_auto_switch,
|
|
line_in_backoff,
|
|
note_line_failure,
|
|
)
|
|
from xray_fluent.profiles.models import Node
|
|
|
|
ZONE = "zone.example"
|
|
|
|
|
|
def _node(node_id: str, host: str) -> Node:
|
|
return Node(id=node_id, name=node_id, server=host, port=443, scheme="vless")
|
|
|
|
|
|
class EntryKeyTests(unittest.TestCase):
|
|
def test_the_second_label_is_the_entry(self) -> None:
|
|
self.assertEqual("rufristal", entry_key(f"x964.rufristal.{ZONE}"))
|
|
self.assertEqual("rurugogo", entry_key(f"q573.rurugogo.{ZONE}"))
|
|
self.assertEqual("timama", entry_key(f"x482.timama.{ZONE}."))
|
|
|
|
def test_an_address_or_a_short_name_is_its_own_entry(self) -> None:
|
|
self.assertEqual("203.0.113.7", entry_key("203.0.113.7"))
|
|
self.assertEqual("[2001:db8::1]", entry_key("[2001:db8::1]"))
|
|
self.assertEqual("server.example", entry_key("server.example"))
|
|
self.assertIsNone(entry_key(""))
|
|
self.assertIsNone(entry_key(None))
|
|
|
|
|
|
class ReplacementTests(unittest.TestCase):
|
|
def _controller(self) -> FakeController:
|
|
controller = FakeController(3)
|
|
controller.state.nodes = [
|
|
_node("n0", f"x964.rufristal.{ZONE}"),
|
|
_node("n1", f"y111.rufristal.{ZONE}"), # the same entry as the active line, and the faster one
|
|
_node("n2", f"q573.rurugogo.{ZONE}"),
|
|
]
|
|
controller.state.selected_node_id = "n0"
|
|
for node, speed in zip(controller.state.nodes, (10.0, 90.0, 40.0)):
|
|
node.is_alive = True
|
|
node.speed_mbps = speed
|
|
node.ping_ms = 50
|
|
return controller
|
|
|
|
def test_another_entry_is_preferred_over_a_faster_line_of_the_failed_entry(self) -> None:
|
|
controller = self._controller()
|
|
self.assertEqual("n2", get_next_node_for_auto_switch(controller).id)
|
|
|
|
def test_the_same_entry_is_still_used_when_nothing_else_is_left(self) -> None:
|
|
controller = self._controller()
|
|
note_line_failure(controller, controller.state.nodes[2], 100.0)
|
|
with patch.object(auto_switch_service.time, "monotonic", return_value=101.0):
|
|
self.assertEqual("n1", get_next_node_for_auto_switch(controller).id)
|
|
|
|
def test_a_failed_line_is_out_for_1_then_5_then_10_minutes_and_then_back(self) -> None:
|
|
controller = self._controller()
|
|
node = controller.state.nodes[2]
|
|
self.assertEqual((60.0, 300.0, 600.0), AUTO_SWITCH_BACKOFF_SEC)
|
|
at = 1000.0
|
|
for expected in (60.0, 300.0, 600.0, 600.0):
|
|
self.assertEqual(expected, note_line_failure(controller, node, at))
|
|
self.assertTrue(line_in_backoff(controller, node.id, at + expected - 1))
|
|
self.assertFalse(line_in_backoff(controller, node.id, at + expected + 1), "never banned for good")
|
|
at += expected + 5
|
|
|
|
|
|
class FreshLineTests(unittest.TestCase):
|
|
def _fresh(self, controller: FakeController, connected_at: float) -> None:
|
|
controller._auto_switch_warmup_until = connected_at + auto_switch_service.AUTO_SWITCH_WARMUP_SEC
|
|
controller._auto_switch_fresh_from = connected_at + AUTO_SWITCH_FRESH_WARMUP_SEC
|
|
controller._auto_switch_fresh_until = connected_at + AUTO_SWITCH_FRESH_SEC
|
|
|
|
def test_a_confirmed_silent_fresh_line_is_left_at_once_without_the_warmup(self) -> None:
|
|
controller = FakeController()
|
|
self._fresh(controller, 100.0)
|
|
_tick(controller, 106.0, link_alive=False) # armed: the verdict of the worker arrived 6 s after the connect
|
|
self.assertEqual([], controller.selected)
|
|
_tick(controller, 107.0, link_alive=False) # the very next tick, no 15 s of dead pings
|
|
self.assertEqual(1, len(controller.selected))
|
|
|
|
def test_before_the_fresh_minimum_nothing_happens(self) -> None:
|
|
controller = FakeController()
|
|
self._fresh(controller, 100.0)
|
|
_tick(controller, 102.0, link_alive=False)
|
|
_tick(controller, 103.0, link_alive=False)
|
|
self.assertEqual([], controller.selected)
|
|
|
|
def test_a_settled_line_keeps_the_slow_rule(self) -> None:
|
|
controller = FakeController()
|
|
_tick(controller, 500.0, link_alive=False)
|
|
_tick(controller, 500.0 + AUTO_SWITCH_DEAD_LINK_SEC - 1, link_alive=False)
|
|
self.assertEqual([], controller.selected)
|
|
_tick(controller, 500.0 + AUTO_SWITCH_DEAD_LINK_SEC + 1, link_alive=False)
|
|
self.assertEqual(1, len(controller.selected))
|
|
|
|
def test_the_switched_away_line_goes_into_back_off(self) -> None:
|
|
controller = FakeController()
|
|
self._fresh(controller, 100.0)
|
|
_tick(controller, 106.0, link_alive=False)
|
|
_tick(controller, 107.0, link_alive=False)
|
|
self.assertTrue(line_in_backoff(controller, "n0", 108.0))
|
|
|
|
|
|
class FreshWorkerTests(unittest.TestCase):
|
|
"""The worker side: 5 s of sending without an answer on a fresh line, 10 s on a settled one."""
|
|
|
|
def setUp(self) -> None:
|
|
# The worker harness of the dead-link tests (a real LiveMetricsWorker with a recording reader and confirmer).
|
|
self.harness = MetricsWorkerPingTargetTests("test_set_ping_target_repoints_and_forces_probe")
|
|
|
|
def _confirms_after(self, seconds: float, *, fresh: bool) -> int:
|
|
module, worker, _reads, confirms = self.harness._watching(verdict=False)
|
|
worker._fresh_pending = fresh
|
|
up, down = module.PING_UNANSWERED_UP_BPS * 2, 0.0
|
|
now = 100.0
|
|
while now <= 100.0 + seconds:
|
|
worker._watch_link(now, down, up)
|
|
now += 1.0
|
|
self.harness._settle(worker)
|
|
return len(confirms)
|
|
|
|
def test_a_fresh_line_is_confirmed_after_five_seconds(self) -> None:
|
|
module = self.harness._watching(verdict=False)[0]
|
|
self.assertEqual(5.0, module.LINK_SUSPECT_FRESH_SEC)
|
|
self.assertEqual(0, self._confirms_after(4, fresh=True))
|
|
self.assertEqual(1, self._confirms_after(6, fresh=True))
|
|
|
|
def test_a_settled_line_is_confirmed_after_ten_seconds(self) -> None:
|
|
self.assertEqual(0, self._confirms_after(8, fresh=False))
|
|
self.assertEqual(1, self._confirms_after(11, fresh=False))
|
|
|
|
|
|
if __name__ == "__main__":
|
|
unittest.main()
|